15ton big heating surface boiler economizer with finned tubes
Boiler economizer is a device that is designed to increase the operating efficiency of a boiler, cutting down on its operational costs over the lifetime of the boiler.
Although the savings on any given day may be relatively small, the impact over time can be significant; some boilers are designed with economizers built in, while in other cases, an economizer can be fitted on after the act.
The boiler economizer acts as a waste heat recovery device, ensuring that this heat does not go unused.
Instead, the heat is used to essentially preheat the water, so that less heat is required to bring the water to a temperature high enough to make steam.
Product name:
Economizer or Coal Economizer, boiler economizer, Serpentuator tube.
Economizer is a mechanical device intended to reduce energy consumption, or to perform another useful function like preheating a fluid. The economizer is used for other purposes as well boiler, powerplant, and heating, ventilating, and air-conditionin(HVAC) uses are discussed in this article. In simple terms, an economizer is a heat exchanger.
Economizer is the boiler tail flue in the boiler feed water heated to the steam pressure under the saturated water heating surface, because it absorbs relatively low temperature flue gas, reducing the smoke exhaust gas temperature, saving energy, improve the efficiency.
Accessory:
The boiler economizer acts as a waste heat recovery device, ensuring that this heat does not go unused.
Instead, the heat is used to essentially preheat the water, so that less heat is required to bring the water to a temperature high enough to make steam
boiler parts Heat exchanger H Fin tube economizer used in utility boilers, industrial boilers, marine power, such as the tail of heat exchanger components.
Performance characteristics :
1. Excellent anti-wear performance
2. Less fouling
3. Compact space
4. Welded Joints less
5. Stability
Data sheet for reference :
Boiler capacity | Economizer model | Working pressure (Mpa) | Finned tube size (mm) | Finned tube qt'y (pcs) | Finned tube diameter (mm) |
2t/h | L1000-1.6-¢50*24 | 1.6 | 1000 | 24 | 50 |
2t/h | L1000-1.6-¢50*32 | 1.6 | 1000 | 32 | 50 |
4t/h | L1000-1.6-¢50*36 | 1.6 | 1000 | 36 | 50 |
4t/h | L1000-1.6-¢50*48 | 1.6 | 1000 | 48 | 50 |
6t/h | L1500-1.6-¢60*60 | 1.6 | 1500 | 60 | 60 |
8t/h-10t/h | L1500-1.6-¢60* 80 | 1.6 | 1500 | 80 | 60 |
15t/h | L1500-1.6-¢60*120 | 1.6 | 1500 | 120 | 60 |
20t/h | L2000-1.6-¢60*120 | 1.6 | 2000 | 120 | 60 |
20t/h | L2500-1.6-¢60*100 | 1.6 | 2500 | 100 | 60 |
25t/h | L2000-1.6-¢60*160 | 1.6 | 2000 | 160 | 60 |
25t/h | L2500-1.6-¢60*120 | 1.6 | 2500 | 120 | 60 |
25t/h | L2500-1.6-¢60*160 | 1.6 | 2500 | 160 | 60 |