Add to Cart
China Made 30 Liter Oil Gas Fired Hot Water Boiler Gas Steam Engine Boiler
Gas boiler fuel gas hot water boiler heating breeding greenhouse
1. Automatic temperature control: automatically adjust the boiler load according to the outdoor temperature control boiler input quantity;
2, automatic water temperature control: according to the water temperature sensor signal to control the automatic start and stop of the burner and the size of the fire conversion. Real-time display of the outlet water temperature and return water temperature; double safety protection for water temperature;
3, automatic pressure control: real-time monitoring of system pressure, overpressure and underpressure safety interlock protection;
4. Fully automatic water supply control: control the rotation frequency of the make-up water pump according to the remote pressure gauge signal to ensure that the boiler pressure is within the set range;
5, burner control: according to the load control burner start and stop and large and small fire conversion, real-time monitoring of the combustion operating state, the burner failure can be remotely reset;
6. Safety control: boiler over-temperature and over-pressure protection, boiler water level over-limit protection, make-up water pump, burner failure, smoke temperature high fault interlock protection;
7, circulation pump control: dual pump settings, one for one, automatic switching;
8, time switch machine: can be turned on and off according to user needs. Generally it is an automatic four-time switch.
Product advantages:
1. Excellent configuration: supporting the world burner, fully automatic operation:
2. High efficiency and energy saving: the thermal efficiency is between 90% and 95%.
Large space combustion chamber and reasonable structure layout, greatly improve the fuel - steam, fuel - hot water heat exchange capacity.
3. Meet the requirements of environmental protection: large combustion chamber space, coupled with high-quality and reliable imported burner, fuel can be completely burned, greatly reducing the emission of harmful components in the smoke.
It has been tested by legal departments.
4. Reasonable design: horizontal internal combustion three-way wet back design of natural gas steam boiler, 100% corrugated furnace, with good thermal scalability.
The overall design of water and fire, sufficient heating area and reasonable structure layout are the guarantee of high efficiency operation of boiler.
5. Easy maintenance: the natural gas steam boiler is equipped with movable smoke box door before and after the boiler, with fire observation hole and inspection hole at the back, which can be entered into the furnace for inspection and cleaning.
The manhole is opened on the furnace body, and the structural design fully considers the convenience of maintenance in the future.
Oil water boiler 0.35MW-14MW Oil Gas Fired hot water boiler technical datasheet
Main technical parameters of CWNS oil (gas) atmospheric pressure and pressure hot water boiler | |||||||||||||||
Project model | CWNS, WNS series hot water boiler | ||||||||||||||
Rated calorific value (MW) | 0.35 | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 5.6 | 7 | 8.4 | 10.5 | 12.6 | 14 | |
Working pressure (MPa) | Normal pressure / pressure | ||||||||||||||
Outlet water temperature (°C) | 85/115 | ||||||||||||||
Backwater temperature (°C) | 60/70 | ||||||||||||||
Boiler thermal efficiency (%) | 91—95 | ||||||||||||||
Feed water temperature (°C) | 20 | ||||||||||||||
Fuel consumption | Diesel (Kg/h) | 32 | 65.4 | 98 | 131 | 196.2 | 261.6 | 327 | 392.4 | 523.2 | 654 | 784.8 | 981 | 1177 | 1310 |
Heavy oil (Kg/h) | 34 | 69.5 | 105 | 139 | 208.5 | 278 | 347.5 | 417 | 556 | 695 | 864 | 1042.5 | 1251 | 1390 | |
Natural gas (m3/h) | 39.5 | 79.3 | 119 | 159 | 237.9 | 317.2 | 396.5 | 475.8 | 644 | 793 | 951.6 | 1189.5 | 1427.4 | 1586 | |
Liquefied gas (m3/h) | 14.2 | 29 | 43.5 | 58 | 87 | 116 | 145 | 174 | 232 | 290 | 348 | 435 | 522 | 580 | |
City gas (m3/h) | 84 | 168.5 | 253 | 337 | 505.5 | 674 | 842.5 | 1011 | 1348 | 1685 | 2022 | 2527.5 | 3033 | 3370 | |
Boiler transportation | Length (mm) | 2800 | 3500 | 4100 | 4500 | 4700 | 4550 | 5700 | 6300 | 7000 | 7200 | 7840 | 8100 | 8230 | 8250 |
Width (mm) | 1600 | 1600 | 1900 | 2000 | 2110 | 2210 | 2500 | 2600 | 2700 | 2800 | 2860 | 3100 | 3100 | 3400 | |
High (mm) | 2000 | 2100 | 2310 | 2360 | 2470 | 2580 | 2800 | 2900 | 3200 | 3300 | 3300 | 3400 | 3400 | 3550 | |
Total power consumption (KW) | 2.3 | 6.7 | 11 | 13.5 | 19 | 21 | 23.5 | 26 | 37 | 37 | 42 | 45 | 52 | 52 | |
Chimney diameter (mm) | 250 | 350 | 430 | 450 | 450 | 550 | 650 | 650 | 650 | 800 | 800 | 900 | 1200 | 1200 | |
Shipping weight (T) | 3.2 | 4.7 | 4.8 | 5.4 | 8 | 9.78 | 13.4 | 15.4 | 17.4 | 17.4 | 23.8 | 30 | 31.6 | 34.5 | |
Heating area (m2) | 3000 | 6000 | 900 0 | 1200 0 | 1800 0 | 2400 0 | 3000 0 | 3600 0 | 4800 0 | 6000 0 | 7200 0 | 900 00 | 1080 00 | 1200 00 | |
Water supply capacity (t) | 7 | 15 | 22 | 30 | 45 | 60 | 75 | 90 | 120 | 150 | 180 | 225 | 270 | 300 |
Oil water boiler Vocume hot water boiler
Project / model | ZKW0.7-85/60-Y(Q) | ZKW1.05-85/60-Y(Q) | ZKW1.4-85/60-Y(Q) | ZKW1.75-85/60-Y(Q) | ZKW2.1-85/60-Y(Q) | ZKW2.8-85/60-Y(Q) | ZKW3.5-85/60-Y(Q) | |
Heat medium water capacity (L) | 410 | 520 | 568 | 700 | 830 | 980 | 1250 | |
Rated calorific value (Mw/h) | 0.7 | 1.05 | 1.4 | 1.75 | 2.1 | 2.8 | 3.5 | |
Rated calorific value | 60 | 90 | 120 | 150 | 180 | 240 | 300 | |
Fuel consumption | Light diesel oil (Kg/h) | 64 | 96 | 128 | 160 | 192 | 256 | 320 |
Heavy oil (Kg/h) | 67.3 | 100 | 134 | 168 | 202 | 269 | 363 | |
Natural gas (m3/h) | 165 | 116 | 155 | 193 | 232 | 310 | 387 | |
City gas (m3/h) | 77 | 247 | 330 | 412 | 494 | 659 | 824 | |
Liquefied gas (m3/h) | 29 | 44 | 58 | 73 | 88 | 117 | 146 | |
Heat Exchanger | Material/structure | Stainless steel | ||||||
Working pressure (MPa) | 1 | |||||||
Heating | Maximum calorific value | 36 | 54 | 72 | 90 | 108 | 144 | 180 |
Warm water circulation | 36 | 54 | 72 | 90 | 108 | 144 | 180 | |
Pressure loss | 2.2 | 3 | 2 | 2.6 | 2.5 | 3.5 | 3.3 | |
Heating outlet (DN) | 65 | 80 | 80 | 100 | 125 | 125 | 133 | |
Heating area (m2) | 6000 | 9000 | 12000 | 15000 | 18000 | 24000 | 30000 | |
Special for hot water | Maximum calorific value | twenty four | 36 | 48 | 60 | 72 | 96 | 120 |
Water supply capacity (m3/h) | 6 | 9 | 12 | 15 | 18 | twenty four | 30 | |
Hot water temperature | 50 | |||||||
Pressure loss | 2 | 0.6 | 1.5 | 1.8 | 1.5 | 1.8 | 2 | |
Water outlet diameter (DN) | 40 | 65 | 65 | 80 | 100 | 100 | 125 | |
Voltage | Voltage (V) | 220/380 | ||||||
Total power consumption | 2.2 (2.6) | 3.7 (4.1) | 5.0 (6.5) | 7.5(9) | 11 (2.5) | 15 (16.5) | 18.5(20) | |
Blower power consumption | 2.2 | 3.7 | 5 | 7.5 | 11 | 15 | 18.5 | |
Oil pump power consumption | 0.4 | 0.4 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | |
size | Chimney diameter (mm) | 350 | 350 | 400 | 450 | 500 | 550 | 600 |
Long (m) | 2700 | 3200 | 3400 | 4050 | 4700 | 4900 | 5500 | |
Width (m) | 1365 | 1365 | 1600 | 1600 | 1600 | 1800 | 2020 | |
High (m) | 2345 | 2400 | 2500 | 2580 | 2580 | 2630 | 2700 |