Add to Cart
Gold supplier industrial electric heating boiler 0.24/0.35/0.48/0.7/1.05/1.4/2.8t/h electric heating steam boiler
Features:
1. Electric heating steam boiler adopts reasonable structure design, has large steam space and excellent steam quality.
2. Automatic and intelligent control technology is adopted without special personnel on duty.
The working mode is flexible and can be switched freely between manual/automatic modes.
3. according to the needs of users can set the boiler automatic operation period, a day can be set up a number of different working periods, so that the boiler automatically start different heating elements.
Each heating group cycle cutting, the contactor use time, frequency is the same, can effectively improve the service life of the equipment.
4. The pressure is automatically controlled by the controller. At the same time, when the load changes, the feed pump and electric heating pipe can be automatically started and stopped.
5. Perfect safety protection function.
Such as leakage protection, water shortage protection, grounding protection, steam overpressure protection, overcurrent protection, power protection and so on.
Advantages
1. An Electric Heating Steam Boiler is a pressure vessel device that converts electrical into heat and then heat the water to produce steam.
2. The piezoelectric furnace with a water storage capacity of 30L or more at the highest safe water level is an electric heating boiler;
3. The Electric Heating Steam Boiler adopts Japan Fuji temperature control instrument, using PID self-tuning intelligent temperature control technology, the control precision can reach the temperature of about ±1 °C, and accurately control the temperature range used;
4. The heating main power supply uses solid-state module non-contact switch circuit, adapt to frequent switching, and no interference to the power supply network. And has anti-dry burning.
5. Electric Heating Steam Boiler Can be designed according to user requirements to add hot oil cooling system to meet the production process requirements of rapid cooling after heating;
6. To achieve centralized control of the boiler.
According to this automated system, the automatic timing switching of the boiler in the boiler room is realized, thereby realizing the circulating operation of the gas boiler, which not only can realize the energy saving of the boiler heating, but also can effectively extend the service life of the boiler.
Electric Heating Steam Boiler data sheet as follow (for reference only) :
WDR Series Electric Heating Steam Boiler - Technical Parameter | ||||||||
Model | WDR0.75-1.0 | WDR1-1.0 | WDR1.5-1.0 | WDR2-1.0 | WDR3-1.0 | WDR4-1.25 | ||
Project | unit | |||||||
Rated evaporation | t/h | 0.75 | 1 | 1.5 | 2 | 3 | 4 | |
Fixed work stress | MPa | 1 | 1 | 1 | 1 | 1 | 1.25 | |
Saturated vapor temperature | °C | 184 | 184 | 184 | 184 | 184 | 193 | |
input power | KW | 540 | 720 | 1080 | 1440 | 2160 | 2880 | |
Input Current | A | 810 | 1080 | 1620 | 2160 | 3240 | 4320 | |
Rated voltage | V | 380 | ||||||
Power × number of groups | KW×P | 36×15 | 36×20 | 36×30 | 36×40 | 36×60 | 36×80 | |
a main steam valve caliber | DN | 40 | 40 | 65 | 65 | 80 | 100 | |
b safety valve caliber | DN | 2×40 | 2×40 | 2×40 | 2×40 | 2×40 | 2×40 | |
c inlet diameter | DN | 40 | 40 | 40 | 40 | 40 | 40 | |
d drain valve caliber | DN | 40 | 40 | 40 | 40 | 40 | 40 | |
Boiler dimensions | L | Mm | 2800 | 2950 | 3450 | 3500 | 3950 | 4100 |
L1 | Mm | 2400 | 2500 | 3050 | 2880 | 3200 | 3550 | |
W | Mm | 1800 | 1900 | 2180 | 2000 | 2100 | 2480 | |
W1 | Mm | 1550 | 1600 | 1430 | 1880 | 1980 | 2120 | |
H | Mm | 1550 | 1600 | 2100 | 2500 | 2650 | 2980 | |
H1 | Mm | 1300 | 1350 | 1850 | 1900 | 2100 | 2200 | |
Control cabinet size | A long | Mm | 1200 | 1200 | 1500 | 1500 | 1800 | 2100 |
B wide | Mm | 500 | 600 | 600 | 600 | 600 | 600 | |
C high | Mm | 1800 | 800 | 2000 | 2000 | 2200 | 2200 | |
weight | Kg | 2300 | 2850 | 3220 | 3550 | 4100 | 5200 |