Yong Xing Boiler Group Co.,Ltd

Yong Xing Boiler Group Co.,Ltd Service customer with profession

Manufacturer from China
Site Member
6 Years
Home / Products / Biomass Steam Boiler /

Automatic Rice Mill Steam Boiler Wood Powered Steam Generator 1-25 T/H Capacity

Automatic Rice Mill Steam Boiler Wood Powered Steam Generator 1-25 T/H Capacity

Ask Latest Price
Brand Name :YONGXING
Model Number :DZL/SZL
Certification :ISO9001,ISO14001,SGS,BV
Place of Origin :HENAN
MOQ :1set
Price :negotiable
Payment Terms :T/T, L/C, Western Union
Supply Ability :USD1000/SET
Delivery Time :10-15days
Packaging Details :Nude packing,Package with Steel Box,or Wooden Box
Burner :Riello, Baltur,or Optional
Control System :Automatic
Warranty :18months
Structure :Water fire tube
Burning Style :Layer Combustion
Drum Placement :Horizontal Boiler
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Manufacturers Direct Selling DZL/SZL Wood Pellet Fuel Biomass Fired Steam Boiler with 1-25t/H Capacity

1. Brief Introduction

The biomass boiler is a single-drum three-return hybrid boiler. The company specializes in fuel collection, transportation and delivery methods for different characteristics of biomass fuels. And for the structure of different boilers, configure the appropriate combustion system and air distribution. It solves the problems of coke in the furnace, insufficient fuel combustion and easy corrosion of the heated surface of the tail, which are often taken care of by traditional biomass boilers.


The three return process is as follows:

1, the biomass pellet fuel falls from the coal hopper to the grate, and after entering the furnace, the flue gas passes through the rear arch to enter the tail of the boiler (the first return journey).

2. the tail of the boiler passes through the convection flue before entering the boiler,The second (return).

3. then enters the rear smoke box through the threaded pipe bundle (third return), and finally enters the economizer.

The dust collector is drawn by the induced draft fan and discharged to the atmosphere through the chimney.


Boiler fuel: waste wood, straw, bagasse, palm shell, biomass pellets, etc.


Combustion method: circulating fluidized bed, water-cooled vibrating grate, reciprocating grate, chain grate, (water-cooled) fixed grate, lower servo, etc.

2. Boiler features:
1). The boiler type is a horizontal quick-install boiler, and the water circulation mode is natural circulation. The boiler heat exchange system is composed of a drum, a left and right header, and a water-cooled wall, and the main heating surface is designed to install a furnace water wall. In addition, the main heating section of the boiler is made of seamless steel pipe for 20# low and medium pressure boiler, and the drum is made of special steel plate for boiler. The left and right headers are made of seamless steel tubes.
2). The upper furnace wall is assembled and factoryized by the factory. The lower furnace wall is composed of refractory bricks, silicate fiber and insulation material. The fuel enters the furnace through the gate, and the coal slag falls into the slag hopper during the operation of the grate. Finally discharged by the spiral slag machine.
3). The boiler is equipped with special combustion equipment. The layer combustion is the main combustion mode, which assists the suspension combustion or the laminar combustion and suspension combustion to ensure that the fuel is fully combusted and burned.
4). Reasonably arrange the heating surface of the boiler, the fuel can fully burn the aerodynamic field, and solve the problem of insufficient combustion and corrosion of the tail heating surface.
5). Reasonably design the boiler furnace, optimize the furnace outlet temperature and convection heating surface flow rate, reduce boiler ash or wear.
6). Avoid tube plate cracks: The flue of the boiler is designed on both sides of the main body, which not only allows the flue gas to smoothly enter the front smoke box, but also effectively reduces the temperature of the pipe and minimizes the crack of the boiler due to temperature stress. .
7). High degree of automation: digital integrated controller, can set the automatic controller combustion condition according to the user, easy to operate, automatic ignition, automatic feeding, automatic cleaning, gas boiler operation is equally convenient.

3. Description-----Introduction to boiler regulation system
1). Boiler steam pressure automatic adjustment system
The boiler steam pressure automatic regulation system control system enters the working state, and the system works normally when the combustion conditions are met. Once the steam pressure in the boiler is above the set upper pressure limit, the control system outputs a stop signal until the steam pressure returns to normal.
2). Water supply automatic control system
The water pump is started and the water supply system works normally. The water level difference sensor detects the water level signal and keeps the water level of the drum stable, thus maintaining normal steam generation. At the same time, the water level adjustment meter can clearly display the boiler water level.

4. The details table of auxiliary paraments is as follows.

Matching auxiliary Type
Chain Grate travelling grates OR flake type chain grates
Induced Draft Fan GY1-18 4#Right 0°
Electromotor Y 132S-4B3
Forced Draft Fan 4-72-3.2A Right 315°
Electromotor Y 90L-2
Electric Pump JGGC2-8X13
Electromotor Y 90L-2
Govenor Stepless speed governor
Electromotor YCT112-4A
Ash Extractor Screw type
Electromotor Y 90S-6
Dust Collector Multi-tube XTD-1

5. The more details of echnical paraments for DZL boiler is list in the table below

Data DZL1-T DZL2-T DZL3-T DZL4-T DZL6-T
Rated evaporation capacity t/h 1 2 3 4 6
Rated working pressure MPa 0.7/1.0/1.25 0.7/1.0/1.25 1.0/1.25 1.25/1.6 1.25/1.6
Rated steam temperature ℃ 170/184/194 170/184/194 184/194 194/204 194/204
Water-supply temperature ℃ 20 20 20 20 20
Body Heated area m2 6 54 83.5 115 186
Economizer Heated area m2 10.56 27.6 41.2 53 87.2
Chain Grate area m2 2.3 2.3 4.1 4.1 5.85
Exhaust temperature (℃) 120 120 120 125 125
Maximum shipping weight ton 19 25 28 32 43
Dimension(L*W*H)
mm
4500×2000×3200 5900×2200×3400 6200×2200×3450 6700×2400×3450 7700×2600×3600

6. The more details of echnical paraments for SZL boiler is list in the table below

TWO PART ASSEMBLED BOILER
boiler model Unit SZL6-1.25/1.6-AII SZL8-1.25/1.6-AII SZL10-1.25/1.6-AII SZL12-1.25/1.6-AII SZL15-1.25/1.6-AII SZL20-1.25/1.6-AII SZL25-1.25/1.6-AII
capacity ton/h 6 8 10 12 15 20 25
rated pressure Mpa 12.5/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6
rated steam temeperature 193/204 193/204 193/204 193/204 193/204 193/204 193/204
feed water temperature 105 105 105 105 105 105 105
radiation area m2 18.19 22.14 25.8 25.8 34.117 53.78 99.21
convection area m2 121.9 158.86 200.38 250.17 331.616 411.8 457.78
economizer area m2 53.13 104.64 130.8 174.4/261.1 117.72/117.2 212.4 476.16
valid grate area m2 7.55 9.34 10.98 12.78 16.24 20.84 24.76
applicable fuel COAL COAL COAL COAL COAL COAL COAL
exhaust gas temperature 165.78/169.85 161/165 160/162 158/150 156.7/159.4 153/159 152/156
design efficiency % 80.11/79.44 79.95/79.98 80.55/80.28 80.68/80.72 80.48/80.56 81.09/80.77 81.38/81.26
fuel consumption kg/h 863.28/874.78 1153.42/1161.38 1430.96/1442.74 1714.5/1721.8 2167.89/2164.7 2868.63/2884.7 3551/3556
max part size for delivery mm 7100*2800*3500
7300*2540*2330
7300*3000*3500
7400*2700*2330
7600*3200*3500
7700*2900*2330
7600*3200*3500
8500*2900*2330
7350*3373*3505
8904*3370*1100
7814.7*3573*3511
9439*3768*1100
8478*2600*2740
Bulk packing

Automatic Rice Mill Steam Boiler Wood Powered Steam Generator 1-25 T/H Capacity

Welcome inquiry more specifications if u need

China Automatic Rice Mill Steam Boiler Wood Powered Steam Generator 1-25 T/H Capacity for sale

Automatic Rice Mill Steam Boiler Wood Powered Steam Generator 1-25 T/H Capacity

Inquiry Cart 0